A. Bulk Milk Cooler Tank
Capacity (rated and gross): 2.5kl â 2.7kl
Make and Model.: OCL/2.5D/BMC
Material used for construction (SS 304/316): S.S. 304
Shape & Orientation: Horizontal semi Cylindrical
Overall dimensions and weight: 2800L X 1750W X 2THK
Thickness of inner and outer SS shells: 2mm & 2mm
Number of agitator (s), RPM: 20-28 RPM 1 no. agitator CG make life time lubricated
CIP facility: Manual or automatic with the details: Manual
Type, thickness and efficiency of insulation: Insulation by injection of high density (40kg/cu.m) polyurethane foam 100 mm insulation
Facility to measure milk volume (dip stick etc.) S.S. 304 OCL dip stick
B. Refrigeration Unit
Make, model and size of compressor (s) at operating conditions 00 C evaporating & 600 C Condensing temperature: Emerson
KHG572 MAED 512 X1 NO.
Make, model and size of condenser(s): As specify by Emerson
Capacity of compressor (s) (Kcal/hr) at evaporating & condensing temperatures: 15120 Kcal/hr X 1 Nos. (60000 BTU/HR)
Capacity of condenser & no. of fans.: 2fan/ Unit
Receiver size & capacity: Specify by Emerson
Thermostatic expansion valve, make, size, capacity: ALCO X 1 Nos.
Overall dimensions and weight of the unit: 703X676X1048 X 1 Nos. 200 KG.
Type of refrigerant: R22
-
Design Parameters
Ambient temperature considered for design: 480C
Maximum cooling time considered for ALL & SECOND Milking. For All Milking 3.5 hrs
Temperature range considered for ALL & SECOND
Milking.: i.e. for brimful capacity not more than 3.5 hrs
E. Electrical :
Connected load in Watts & Amperes for:
Compressor(s): 10.2Amp & 6100 W X 2 Nos.
Condenser fan (s) : 2Amp X 2Nos.
Agitator (s) : 3Amp X 1 (20-28RPM)
Milk pump: 2.5 Amp X 1
Water heater
Maximum / surge current drawn by the compressor (s)(during starting).: 55Amp