Humidity Or Stability Test Chamber



Humidity Or Stability Test Chamber

Product Code : 01

Product Specification
Humidity Or Stability Test Chamber
  • Precise Hot Air & Humidity
  • Better Mineral / Glasswool / Puff Insulation Keep the surface Temperature comfortable & Avoid Heat & Humidity Loss.
  • Silent Hot Air Blower, Unique design of Air Circulation & Humidity circulation & improved Temperature / Humidity distribution.
  • Unique design of Ventilation.
  • Polish 304 grade of S. Steel interior Corrosion resistant long life operation
  • Kanthal A-1 Tubular heater is fitted for better circulation
  • Safety controller are provided with Digital Temp. Controller Cum Indicator
  • Kanthal A-1 steel Tubular heater J shape is fitted in the steam Bath for long life & better result.
  • Full feature with Temp. Controller i.e. Thermostate Bi-Metalic Capillary type for both Dry & Wet Temp. Control or Digital Temp. Controller Cum Indicator & Microprocessor Based PID Temp. Controller Cum Indicator
  • Choose among the models with window front glass door or inner Perspex / Acrylic sheet Door with full view to observe the Test process inside the chamber while keep Temperature uninterrupted.
  • Angle Iron frame with castor wheel for easy movement (for Refrigerated model )
  • Fitted with 02 Nos. Fan for cooling & heating (For Refrigerated Model)
  • Filled with 02 Nos. Circulation motor for water injection in routine model inside the control unit & Chamber.
  • Humidistate is placed inside the chamber to control requested humidity.
  • Humidity can be controlled by Digital Temp. & Humidity (Both automatically on customer requirement) Wet Temp. is controlled by Bi-Metalic Thermostate Connected to Water Bath placed in the control unit having water level. (Nozzle for Water inlet & outlet & overflow)
Applications: Tissue Culture, Pharmaceuticals, Agriculture, Cable Industry, Paper , PVC & Cement Industries Electrical Industries. 

Specifications

Model

SI 1.09/ 1.10
Heating/ Cooling

SI 1.09 A/ 1.10 A
Heating/ Cooling

SI 1.09 B/ 1.10 B
Heating/ Cooling

SI 1.09 C/ 1.10 C
Heating/ Cooling

Capacity (Ltrs.)

95

147

225

335

Interior (mm)

450 x 450 x 450

450 x 450 x 700

605 x 605 x 605

605 x 605 x 900

Heater Wattage "W" (Dry)

250 W

250 W

250 W

250 W

Heater Immersion Wattage (Wet)

1 K W

1 K W

1.5 K W

1.5 K W

Shelves

2

2

2

3

Dimensions are expressed in (Width x Depth x Height)


Technical Parameters

Temperature Range

Ambient to 45oC

Temperature Stability

+-1oC

Housing Material

CRC / Mild Steel Sheet duly Powder Coated

Power Consumption

220/230V, AC +- 10% 50Hz Single Phase

Safety Function

Water Level & Low water level cut off alarm (On customer request)

Optional

RS 232 Communication Interface

Duty Cycle

Continuous

Interior

S.S. 304 Polished Sheet

Humidity Range

Ambient to 95% +-3% (For Routine Model)

Temp. Range

10 - 50°C (For Cooling Refrigerated Model)

Humidity Range

55 - 92% +-3% (For Cooling Refrigerated Model)

Compressor

Kirloskar/ Tecumseh As per model requirement (For Cooling below Ambient)

Voltage Stabilizer

Required for Cooling (Refrigerated Model as per size/ model)

Refrigerant

R 134/22 (For Cooling Model)

Optional

Digital Timer
Wet & Dry Thermometer for Calibration

Precaution

Don't use the Instrument without water

<< Back


OFFICE ADDRESS:-

Scientific International, New Delhi
Ms. Meenakshi Sharma (Director)
1590, Madarsa Road, Behind Oberoi Glass House, Kashmere Gate
Delhi - 110006, India 
 

Humidity Or Stability Test Chamber
Humidity Or Stability Test Chamber
Automatic Weather Station
Automatic Weather Station
Balances
Balances
Bio Chemistry Analyser
Bio Chemistry Analyser
Biological Safety Cabinets
Biological Safety Cabinets
Bulk Density Appartaus
Bulk Density Appartaus
Bursting Strength Tester
Bursting Strength Tester
Centrifuge
Centrifuge
Lab Chemicals
Lab Chemicals
Deep Freezer
Deep Freezer
Flame Photometer
Flame Photometer
Laboratory Hot Plate
Laboratory Hot Plate
Laboratory Glassware
Laboratory Glassware
Lypholyser
Lypholyser
Melt Flow Indexer
Melt Flow Indexer
Research Microscopes
Research Microscopes
UV Vis Spectrophotometer
UV Vis Spectrophotometer
Water & Soil Analysis Kit
Water & Soil Analysis Kit
Orbital Shaking Incubators
Orbital Shaking Incubators
BOD Incubator
BOD Incubator
Fully-automatic Hematology Analyzer
Fully-automatic Hematology Analyzer
Biology Lab Instruments
Biology Lab Instruments
Electrophoresis Unit
Electrophoresis Unit
Electronic Total Station
Electronic Total Station
Anaesthesia Machine
Anaesthesia Machine
Bursting Strength Tester
Bursting Strength Tester
 Specific Gravity Balance
Specific Gravity Balance
Laboratory Plasticwares
Laboratory Plasticwares
Gold Melting Muffle Furnace
Gold Melting Muffle Furnace
 Hookes Law Apparatus
Hookes Law Apparatus
Air Permeability Testers
Air Permeability Testers
Rapid Moisture Meter
Rapid Moisture Meter
Morinda Citrifolia
Morinda Citrifolia
Bulk Milk Cooler
Bulk Milk Cooler
Organic Compost Fertilizer
Organic Compost Fertilizer
Chamomile Chinese Extract
Chamomile Chinese Extract
Clove Oil
Clove Oil
424, S.G Shopping Complex, D.C. Chowk, Sector-9, Rohini, Delhi - 110085, India
Mrs. Meenakshi Sharma (Director,Sales)

Mobile : +919899890998
Phone : 91-11-27552087/27553276
Fax : 91-11-27553276
Send Mail
Send SMS
   Call Me Free